If you still worry about your CDCS exam; if you still doubt whether it is worthy of purchasing our software, what you can do to clarify your doubts is to download our CDCS free demo. Once you have checked our demo, you will find the study materials we provide are what you want most. Our target is to reduce your pressure and improve your learning efficiency from preparing for CDCS Exam.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.

>> CDCS Lead2pass Review <<

CDCS Latest Test Simulations & New CDCS Test Voucher

The reality is often cruel. What do we take to compete with other people? More useful certifications like CDCS certificate? In this era of surging talent, why should we stand out among the tens of thousands of graduates and be hired by the company? Perhaps the few qualifications you have on your hands are your greatest asset, and the CDCS Test Prep is to give you that capital by passing exam fast and obtain certification soon. Don't doubt about it. More useful certifications mean more ways out. If you pass the CDCS exam, you will be welcome by all companies which have relating business with CDCS exam torrent.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q42-Q47):

NEW QUESTION # 42
When designing a data center network, your company wants to minimize the number of network switches to manage.
What type of physical cabling layout would be the best choice?

  • A. EoR (End of Row) design
  • B. It does not matter as the number of switches is not influenced by the physical cabling layout
  • C. Star network design using coaxial cables
  • D. ToR (Top of Rack) design

Answer: A

Explanation:
An End of Row (EoR) design minimizes the number of network switches, as multiple racks can share a single switch at the end of a row, reducing switch counts and simplifying management. This design centralizes network switching to fewer points, which reduces the complexity and number of switches required compared to a Top of Rack (ToR) design, where each rack typically has its own switch.
Detailed Explanation:
In EoR designs, each row has a single network switch that handles the connections for all racks within that row. This reduces the number of individual switches needed and centralizes network management, which is ideal for minimizing equipment and simplifying infrastructure in the data center.
EPI Data Center Specialist References:
EPI promotes the EoR design as a way to reduce switch counts and streamline management in data centers. This configuration allows for easier scaling and maintenance while maintaining efficient network connectivity.


NEW QUESTION # 43
In which stage of the data center life cycle does commissioning take place?

  • A. Operate/optimize
  • B. Implement
  • C. Design
  • D. Retire

Answer: B

Explanation:
Commissioning occurs during the Implementation stage of the data center life cycle. This phase involves the final testing and verification of systems and equipment to ensure they meet design specifications and operational requirements before the data center goes live.
Detailed Explanation:
The Implement phase includes activities such as installation, configuration, and testing. Commissioning is a crucial step that validates the performance and reliability of all critical systems, including power, cooling, and network infrastructure, to ensure they operate as intended under various conditions. Proper commissioning helps identify and resolve any issues before the data center becomes fully operational.
EPI Data Center Specialist References:
EPI training emphasizes that commissioning is essential for verifying that the data center meets design and performance criteria, aligning with best practices in data center project management to minimize risks and ensure readiness for operation.


NEW QUESTION # 44
Three data centers are benchmarked on facilities energy efficiency.
Data center A has achieved a PUE of 2.45.
Data center B has achieved a PUE of 1.20.
Data center C has achieved a PUE of 1.90.
Which of the data centers is operating at the highest facility efficiency?

  • A. Data center C
  • B. Data center A
  • C. PUE does not indicate efficiency
  • D. Data center B

Answer: B

Explanation:
A Power Usage Effectiveness (PUE) of 1.20 (achieved by Data Center B) indicates the highest facility efficiency among the three data centers. A lower PUE value signifies better energy efficiency, as it means that a greater proportion of the total energy consumed is used directly for IT equipment rather than for cooling, lighting, or other facility needs.
Detailed Explanation:
PUE is calculated as the ratio of total facility energy to IT equipment energy. A PUE close to 1.0 suggests that almost all the energy is dedicated to computing processes, with minimal overhead. With PUE values of 2.45, 1.20, and 1.90, Data Center B (1.20) operates most efficiently by devoting a higher percentage of its total energy to IT equipment.
EPI Data Center Specialist References:
The EPI curriculum emphasizes PUE as a key metric for data center efficiency, with lower values representing better performance. Achieving a PUE near 1.0 aligns with industry best practices for energy-efficient data center design and operation.


NEW QUESTION # 45
The pipes of a VESDA smoke detection system are installed at the air intake of the air conditioner inside the computer room.
Is this a good practice from an early smoke detection point of view?

  • A. No, it will give a longer reaction time for the smoke detection system and there might also be bypass airflow.
  • B. No, the piping should be installed at the air exhaust of the air conditioner, as there can also be a fire inside the air conditioner itself.
  • C. Yes, as this reduces the amount of piping to be installed in the data center, as all air will go through the air conditioner.
  • D. It depends on the type of gas-based fire suppression which will be installed.

Answer: A

Explanation:
For optimal early smoke detection in a data center, it is crucial that the Very Early Smoke Detection Apparatus (VESDA) system be installed at locations where smoke will be detected as soon as it appears. Positioning the VESDA pipes at the air intake of the air conditioner inside the computer room is not ideal. This placement could result in a delayed detection response and the potential for bypass airflow to occur, which would impede the system's ability to detect smoke effectively.
Detailed Explanation:
When VESDA pipes are installed at the air intake, the detection system relies on the smoke to be drawn into the air conditioning unit before detection can occur. This setup increases the reaction time as the smoke has to travel through the intake and get processed by the air conditioner. Furthermore, bypass airflow-a phenomenon where not all the air containing smoke particles passes through the VESDA pipes-could also delay or even prevent the system from detecting smoke early.
Ideally, VESDA pipes should be positioned where smoke is likely to accumulate first, such as near the ceiling or in the return airflow path to detect smoke at the earliest possible stage. This ensures that the detection system can quickly trigger alarms, providing more time to address potential fire hazards.
EPI Data Center Specialist References:
EPI Data Center Specialist training highlights that smoke detection should prioritize early response capabilities to maximize safety. The preferred installation for VESDA pipes is generally at points where smoke would naturally accumulate, rather than relying on air conditioning intakes where airflow can vary and delay detection. In their course materials, EPI emphasizes minimizing reaction time and reducing the impact of airflow dynamics on smoke detection efficiency.


NEW QUESTION # 46
An MCB needs to be installed in the PDU of an air-conditioner unit.
Which breaking curve should you select?

  • A. C-Curve
  • B. A-Curve
  • C. D-Curve
  • D. B-Curve

Answer: A

Explanation:
For an MCB (Miniature Circuit Breaker) in the PDU of an air-conditioning unit, a C-Curve is recommended. C-Curve breakers are suitable for circuits with moderate inrush currents, such as those experienced in air conditioning units. They provide protection against overloads while accommodating the inrush without nuisance tripping.
Detailed Explanation:
C-Curve breakers trip when currents exceed 5 to 10 times the rated current, making them ideal for devices like air conditioners that experience moderate inrush currents upon startup. This characteristic provides a balance between protection and resilience against startup surges, preventing unnecessary trips while safeguarding the circuit.
EPI Data Center Specialist References:
EPI guidance for data center electrical systems specifies that C-Curve breakers are appropriate for equipment with inrush characteristics similar to air conditioning units, as they help prevent operational interruptions caused by typical surges during equipment start-up.


NEW QUESTION # 47
......

In order to allow you to safely choose NewPassLeader, part of the best EXIN certification CDCS exam materials provided online, you can try to free download to determine our reliability. We can not only help you pass the exam once for all, but also can help you save a lot of valuable time and effort. NewPassLeader can provide you with the real EXIN Certification CDCS Exam practice questions and answers to ensure you 100% pass the exam. When having passed EXIN certification CDCS exam your status in the IT area will be greatly improved and your prospect will be good.